Applied Motion ST10-C-CE User Manual

Page 32

Advertising
background image

32

920-0025 Rev K

3/5/2015

CANopen User Manual

Sub-index 3h contains the inhibit time. This time is a minimum interval for PDO

transmission. The value is defined as multiple of 100μs. It is not allowed to change the value

while the PDO exists (Bit 31 of sub-index 1 is 0).Sub-index 4h is reserved. It does not have to

be implemented, in this case read or write access leads to Abort SDO Transfer (abort code:

0609 0011h).

In mode 254/255 additionally an event time can be used for TPDO. If an event timer exists

for a TPDO (value not equal to 0) the elapsed timer is considered to be an event. The event

timer elapses as multiple of 1 ms of the entry in sub-index 5h of the TPDO. This event will

cause the transmission of this TPDO in addition to otherwise defined events. The occurrence

of the events set the timer. Independent of the transmission type the RPDO event timer is used

recognize the expiration of the RPDO.

Object Type

Sub Number

Record

3

Subindex

Name

Data Type

Access

Type

PDO

Mapping

COS

Default value

00

max sub-index

UNSIGNED8

ro

no

no

2

01

COB-ID used by

RPDO

UNSIGNED32

rw

no

no

$NODEID+0x200

2

02

transmission type

UNSIGNED8

rw

no

no

255

0x1400 - 0x1403 RPDO communication parameter
max sub-index

COB-ID
bit 0-10: COB-ID for PDO, to change it bit 31 must be set
bit 11-29: set to 0 for 11 bit COB-ID
bit 30: 0(1) - rtr are allowed (are NOT allowed) for PDO
bit 31: 0(1) - node uses (does NOT use) PDO

Transmission type
value = 0-240: receiving is synchronous, process after next reception of SYNC object
value = 241-253:

not used

value = 254:

manufacturer specific

value = 255:

asynchronous

*Note 2: Index 1400.01h Default value is 0x200+$NODEID

Index 1401.01h Default value is 0x300+$NODEID
Index 1402.01h Default value is 0x400+$NODEID
Index 1403.01h Default value is 0x500+$NODEID