0x6061 Modes_of_operation_display
The modes_of_operation_display shows the current mode of operation. The meaning of

the returned value corresponds to that of the Modes of Operation option code (index 6060h)

Object Type

Data Type

Access Type

PDO Mapping

COS

Default value

Var

INTEGER8

ro

yes

yes

0

This value of operation mode indicates the current mode of operation.

0x6064 Position_value_calculated
This object represents the calculated value of the position at the current moment in user

defined units.

Object Type

Data Type

Access Type

PDO Mapping

COS

Default value

Var

INTEGER32

ro

yes

yes

0

0x6065 following_error_window
This object shall indicate the configured range of tolerated position values symmetrically

to the position demand value. If the position actual value is out of the following error window,

a following error (Position Limit) occurs. A following error may occur when a drive is blocked,

unreachable profile velocity occurs (Jog mode should be Mode 1), or improperly tuned (Servo

and Step Servo only). The value shall be given in user defined position units. If the value of the

following error window is 0, the following control shall be switched off.

Object Type

Data Type

Access Type

PDO Mapping

COS

Default value

Var

UNSIGNED32

rw

no

No

0

This object is the same functionally as Manufacturer specific object 0x500F.

0x606C Velocity_value_calculated
This object represents the calculated value of the velocity at the current moment in user

defined units.

Object Type

Data Type

Access Type

PDO Mapping

COS

Default value

Var

INTEGER32

ro

yes

yes

0

The value reading from driver should be divided by 240 to change to rps units.

e.g.: a value of 2400 in index 0x606c, means the calculated velocity is 10rps.