Table 28: tpdo transmission types, Table 29: pdo mapping, Tpdo transmission types – Applied Motion ST10-C-CE User Manual

Page 92: Pdo mapping, Tpdo transmission types pdo mapping

Advertising
background image

92

920-0025 Rev K

3/5/2015

CANopen User Manual

TPDO Transmission Types

There are several triggering options for Transmit PDOs, which are controlled by OD en-

tries 1800

h

to 1803

h

, and their associated sub-entries.

Possible TPDO Triggers
SYNC pulse - Node will send TPDO after receiving one or multiple SYNC pulses
Event/Timer - Node will issue TPDO based on an internal event or timer
Remote Request - Node will send TPDO after a remote request

Table 28: TPDO Transmission Types

PDO Mapping

The Applied Motion Products CANopen allows you to map objects to PDOs to allow for

the transfer of application data more efficiently. By using the PDO mapping, the user can map

multiple mappable Objects to a PDO, (max length for a PDO is 8 bytes). The following section

describes the process of a TPDO mapped to several objects.

Table 29: PDO Mapping

0

PDO transmitted on the next SYNC pulse after the statusword has changed

1

PDO transmitted on every SYNC pulse

2-240

PDO transmitted on every n SYNC pulses

254-255

PDO transmitted every time statusword changes, or the Event Timer has expired

TPDO Index

Sub-Index

Mapped To Index

# Bytes

1A01

h

00

h

1A01

h

01

h

6041

h

2

1A01

h

02

h

700A

h

4