Figure 3-2

3.7.3 Alarm Output Port

 Provide external power to external alarm device.
 To avoid overloading, please read the following relay parameters sheet carefully.
 RS485 A/B cable is for the A/B cable of the PTZ decoder.

 T+,T-,R+,R- are four-wire double duplex RS485 port.

T+ T-: output wire

R+ R-: input wire

Relay Specification

M odel:

JRC-27F

Mater ial of the
touch

Silver

Rating
(Resistance
Load)

Rated switch capacity

30VDC 2A, 125VAC 1A

Maximum switch power

125VA 160W

Maximum switch voltage

250VAC, 220VDC

Maximum switch currency

1A

Insulation

Between touches with same
polarity

1000VAC 1minute

Between touches with different
polarity

1000VAC 1minute

Between touch and winding

1000VAC 1minute

Surge voltage

Between touches with same
polarity

1500V (10×160us)

Length of open
time

3ms max

Length of close
time

3ms max

Longevity

Mechanical

50×106 times (3Hz)

Electr ical

200×103 times (0.5Hz)

Temperature

-40℃ ~+70℃