4

Storage
Mode

Support channel record quota setup

Recording
Length

1 to 120 minutes single record duration (Default setup is 60 minutes)

Playback
Repeat
Way

When hard disk is full, system can overwrite previous video file.

Record
Search

Various search engines such as time, type and channel.

Playback
Mode

Various fast play, slow play speeds, manual frame by frame playback
and reverse play mode.

Various File
Switch
Ways

Can switch to previous or next file or any file in current play list.
Can switch to file on other channel of the same time. (If there is a file)
Support file continuous play, when a file is end system auto plays the
next file in the current channel

Playback
Way

Support mark playback

Multi-
channel
Playback

There is 1/4-channel playback mode.

Window
Zoom

Switch between self-adaptive screen/full screen when playback

Partial
Enlargemen
t

When in one-window full-screen playback mode, you can select any zone
to activate partial enlargement function.

Backup
function

Backup
Mode

HDD backup
Support peripheral USB backup device. (Flash disk, portable disk and
etc.)
Support peripheral USB burner.
Support network download and save




Network
Function

Network
control

View monitor channel remotely.
DVR configuration through client-end and web browser
Upgrade via client or browser to realize remote maintenance.
View alarm information such as motion detection and video loss via
client.
Support network PTZ lens control
File download backup and playback
Multiple devices share information via corresponding software such as
professional surveillance software (PSS)
Duplex transparent COM
Network alarm input and output

Zero-channel encoding
Bidirectional audio.


Motion
Detection and
Alarm

Motion
Detection

Zone setup: support 396((PAL 22×18, NTSC 22×15)) detection zones.
Various sensitivity levels.
Alarm can activate record or external alarm or screen message prompt.

Video Loss

Alarm can activate screen message prompt.

External
Alarm

N/A

Manual
Alarm
Control

N/A

Alarm Input

N/A

Alarm
Output

N/A

Alarm Relay N/A