2 net alarm, 3 abnormality – AGI Security SYS-HC0451S2 User Manual

Page 235

Advertising
background image

225

Parameter

Function

Record Delay

System can delay the record for specified time after alarm
ended. The value ranges from 10s to 300s.

Alarm out

Enable alarm activation function. You need to select alarm
output port so that system can activate corresponding
alarm device when an alarm occurs.

Latch

System can delay the alarm output for specified time after
an alarm ended. The value ranges from 1s to 300s.

Show message

System can pop up a message to alarm you in the local
host screen if you enabled this function.

Buzzer

Check the box here to enable this function. The buzzer
beeps when an alarm occurs.

Alarm upload

System can upload the alarm signal to the centre
(Including alarm centre).

Send Email

If you enabled this function, System can send out an
email to alert you when an alarm occurs.

Tour

You need to check the box here to enable this function.
System begins 1-wiindow or multiple-window tour display
among the channel(s) you set to record when an alarm
occurs.

PTZ Activation

Here you can set PTZ movement when alarm occurs.
Such as go to preset X.

5.8.3.2.2 Net Alarm

The network alarm interface is shown as in Figure 5-60.

Network alarm refers to the alarm signal from the network. System does not anti-dither and sensor type

setup. For setup information, please refer to chapter 5.8.3.2.1.

Figure 5-60


5.8.3.3 Abnormality