Esc e, Esc ! w 1 – Compuprint MDP40B Programmer Manual User Manual

Page 157

Advertising
background image

C-15

The command is not accepted (command specification error) if it is sent with
superscript or subscript enabled.

• It is sent with the OCR-A or B Font selected.
• It is sent with a document positioned at the first printing line.
• It is sent inside a printing field.

ESC e

Cancel double height and double width. (Olivetti PR2, PR40+)

ASCII Code

ESC e

Hexadecimal Value

1B 65

Decimal Value

27 101

Cancels the double height setting starting from the current position. As the double
height setting also activates double width, canceling the former feature also cancels
the latter, unless the latter was set previously using ESC 3.

The command is not accepted if it is sent inside a printing field.

ESC ! W 1

Double height. (Olivetti PR2)

ASCII Code

ESC ! W 1

Hexadecimal Value

1B 21 57 31

Decimal Value

27 33 87 49

Sets the printing of double height characters starting from the current position. The
print pitch is not changed. This setting remains active until the relevant cancellation
command is received.

The command is not accepted if it is sent with the OCR-A or B Font selected.

Advertising