C-68

ESC -

Measure document length. (Olivetti PR2, PR40+)

ASCII Code

ESC -

Hexadecimal Value

1B 2D

Decimal Value

27 45

If the document is not inserted, the printer feeds it in, measures its length in
elementary steps and sends the value to the CU by means of the ESC S n command.

The elementary step value is expressed in n/240" or n/216", depending on the value
selected in setup.

When the command has been executed, the position of the document is unknown, so
its next position must be given by an absolute position setting.

The command is not accepted (command specification error) if:

• It is sent inside a printing field.
• A device other than the front paper stand is selected.

ESC } -

Measure document width. (Olivetti PR2)

ASCII Code

ESC } -

Hexadecimal Value

1B 7D 2D

Decimal Value

27 45 125

If the document is not inserted, the printer feeds it in, measures the width in
elementary steps and sends the value to CU by means of ESC S n. The elementary
step value is 1/240"

The command is not accepted (command specification error) if:

• It is sent inside a printing field.
• A device other than the front paper stand is selected.