C-43

ESC : 000

Copy character generator into user memory. (Olivetti PR2, PR40+)

ASCII Code

ESC : 0 0 0

Hexadecimal Value

1B 3A 30 30 30

Decimal Value

27 58 48 48 48

The command transfers the current character generator set into the user memory.

The command is not accepted (command specification error) if:

• It is sent inside a printing field.
• It is sent with the OCR-A or B Font selected, in that these fonts cannot be loaded

into the user memory.

ESC m n 0

Select character generator. (Olivetti PR2, PR40+)

ASCII Code

ESC m n 0

Hexadecimal Value

1B 6D n 30

Decimal Value

27 109 n 48

The command selects the current character generator or the one in the user memory
depending on the decimal value of parameter n.

n Generator

selected

0

Current character generator

1

Character generator in user memory

The command is not accepted if it is sent with the OCR-A or B Font selected.