Test 6 – plasma start, Test 6 – plasma start -26, Test 6 – plasma – Hypertherm Powermax45 Service Manual User Manual

Page 102: Does not, perform test, 26 to check the start, Powermax, Troubleshooting and system tests 5-26, Service manual test 6 – plasma start, Caution

Advertising
background image

TroubleshooTing and sysTem TesTs

5-26

powermax

45

Service Manual

Test 6 – plasma start

Verify that the control board LED is receiving a valid start signal.

1. With the power ON, look at the Start LED on the control board. It should illuminate whenever the torch is

activated.

2. Set the ON/OFF switch to OFF (O). Check the resistance between pins 2 and 3 of J10 on the power board.

With the trigger or start signal engaged, the resistance should be 10 Ω or less. With the trigger or start signal

disengaged, the circuit should read as approximately 3 kΩ. If this test fails, check the torch’s start switch and the

torch wires.
NOTE: If the torch will not fire after completing this test, verify that J10 is connected properly – that the pins are

not offset and the connector is not backwards.

3. Set the ON/OFF switch to ON (I). Measure pin 16 of J7 (or J8 for 400 V CE and 480 V CSA power supplies) to

ground (see Test 2 – power board voltage checks on page 5-19). It should measure as 0 VDC for an open circuit

or 3.2 VDC for a closed circuit. If the values are not correct, replace the power board.

CAUTIoN

While testing, remove the consumables to avoid accidentally firing the torch.

TP 19

W

-

+

-

+

TP 18

R

TP 17

B

192 VDC

192 VDC

J10

J7 (or J8)

J10

Advertising
This manual is related to the following products: