Powermax – Hypertherm Powermax45 Service Manual User Manual

Page 88

Advertising
background image

TroubleshooTing and sysTem TesTs

5-12

powermax

45

Service Manual

Problem

This may mean

Cause

Solution

The power ON LED is

illuminated and the yellow

temperature LED is

illuminated.

The internal system

temperature is either over

or under its operating range

(approximately -30° C to

80° C).

• The power supply is too

cold.

• You have exceeded the

duty cycle. (For more

information about duty

cycle, see the Operation

section.)

• Allow the power supply

to warm up if it has been

extremely cold.

• Check the area around the

system to make sure that

the air flow is not blocked.

• If the duty cycle has been

exceeded, let the system

cool before using it again.

Perform Test 8 – fan

on page 5-27 to make

sure the fan is operating

correctly.

The power ON LED is

blinking.

The incoming voltage is not

correct.

• The incoming voltage

is either too high or too

low (a variance greater

than ±15% of the rated

voltage).

Perform Test 1 – voltage

input on page 5-18 to

check the incoming line

voltage.

The power ON LED is

illuminated and the torch

cap LED is illuminated.

The cap-sensing circuit is

not satisfied.

• The consumables are

loose, improperly installed,

or missing.

• The cap-sensor switch is

faulty.

• Correctly install the

consumables.

Perform Test 7 – torch

cap sensor on page 5-27

to test the cap-sensor

switch.

The power ON LED is

illuminated and the torch

cap LED blinks.

This indicates either a

“torch stuck open” or “torch

stuck closed” situation.

• The consumables are

installed incorrectly,

they are worn, or were

removed while the power

supply is ON.

• The torch plunger is stuck.
• The torch or lead has a

broken wire.

• Check the consumables

for wear and replace if

necessary.

• Make sure they are

properly installed.

• Verify that they are

finger-tight. Try loosening

them 1/8th of a turn and

restarting the power

supply.

Perform Test 5 – torch

stuck open (TSO) or

torch stuck closed (TSC)

on page 5-25 and

replace the torch head

if necessary.

AC

AC

AC

Advertising
This manual is related to the following products: