Powermax, Torch setup 3-12, Service manual – Hypertherm Powermax45 Service Manual User Manual

Page 42

Advertising
background image

torch setup

3-12

powermax

45

Service Manual

T45m shielded consumables

Air flowrate (scfh)

Stainless steel

Hot

320

english

Cold

360

Recommended

Maximum

Arc

current

(amps)

Material

thickness

Torch-

to-work

distance

(in)

Initial pierce

height

Pierce time

delay

(sec)

Cut

Speed

(ipm)

Voltage

(V)

Cut

Speed

(ipm)

Voltage

(V)

30

0.018 in

(26 Ga)

0.06

0.15 in

250%

0.0

360

117

400*

123

0.030 in

(22 Ga)

340

116

400*

121

0.036 in

(20 Ga)

320

115

400*

119

0.060 in

(16 Ga)

0.2

145

111

185

118

45

0.036 in

(20 Ga)

0.06

0.15 in

250%

0.0

300

115

400*

109

0.060 in

(16 Ga)

320

116

400*

125

0.075 in

(14 Ga)

0.1

280

117

360

115

0.105 in

(12 Ga)

0.3

160

117

200

116

0.135 in

(10 Ga)

0.4

120

117

150

118

0.188 in

(3/16 in)

0.5

70

118

85

118

0.250 in

(1/4 in)

0.6

44

120

55

120

0.375 in

(3/8 in)

0.8

30

122

32

121

0.500 in

(1/2 in)

Edge start recommended

14

132

18

128

0.750 in

(3/4 in)

7

140

9

131

* Maximum cut speed is limited by the test table’s maximum speed (400 ipm).