Power supply ratings, Power supply ratings -4, Powermax – Hypertherm Powermax45 Service Manual User Manual

Page 18: Specifications 1-4, Service manual

Advertising
background image

SpecificationS

1-4

powermax

45

Service Manual

Power supply ratings

Rated open-circuit voltage (U

0

)

CSA/CE, single-phase

CE, 3-phase

CSA, 3-phase

275 VDC (CSA/CE single-phase)

275 VDC (CE 3-phase)

278 VDC (CSA 3-phase)

Rated output current (I

2

)

20 A to 45 A

Rated output voltage (U

2

)

132 VDC

Duty cycle at 40° C
(See data plate on power supply for more information on

duty cycle.)

50% (I

2

=45 A, U

2

=132 V)

60% (I

2

=41 A, U

2

=132 V)

100% (I

2

=32 A, U

2

=132 V)

Operating temperature

-10° to 40° C (14° to 104° F)

Storage temperature

-25° to 55° C (-13° to 131° F)

Power factor

200–240 V CSA, 230 V CE, 1-phase

400 V CE, 3-phase

480 V CSA, 3-phase

0.99

0.94

0.93

Input voltage (U

1

) / Input current (I

1

) at

rated output (U

2 MAX

, I

2 MAX

)

(See Voltage configurations in the Power Supply Setup

section for more information.)

200–240 VAC / 34–28 A (200–240 V CSA)

230 VAC / 30 A (230 V CE)*

400 VAC / 10 A (400 V CE)**

480 VAC / 8.5 A (480 V CSA)

Gas type

Air

Nitrogen

Gas quality

Clean, dry, oil-free per ISO

8573-1 Class 1.2.2

99.995% pure

Recommended gas inlet flow and pressure

170 l/min at 6.2 bar (360 scfh at 90 psi)

* Equipment complies with IEC 61000-3-12.
** Equipment complies with IEC 61000-3-12 provided that the short-circuit power S

sc

is greater than or equal to

692 KVA at the interface point between the user’s supply and the public system. It is the responsibility of the installer

or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the

equipment is connected only to a supply with a short-circuit power S

sc

greater than or equal to 692 KVA.

Advertising
This manual is related to the following products: