Extension cord recommendations, Extension cord recommendations -5, Powermax – Hypertherm Powermax45 Service Manual User Manual

Page 27: Power supply setup, Service manual 2-5 extension cord recommendations

Advertising
background image

power supply setup

powermax

45

Service Manual

2-5

extension cord recommendations

Use an extension cord of an appropriate wire size for the cord length and system voltage. Use a cord that meets national

and local codes.

The following tables provide the recommended gauge size for various lengths and input voltages. The lengths in the

tables are the length of the extension cord only; they do not include the power supply’s power cord.

Metric

Input voltage Phase

< 3 m

3–7.5 m

7.5–15 m

15–30 m

30 –45 m

208 VAC

1

10 mm

2

10 mm

2

10 mm

2

16 mm

2

25 mm

2

220 VAC

1

10 mm

2

10 mm

2

10 mm

2

16 mm

2

25 mm

2

200–240 VAC

1

10 mm

2

10 mm

2

10 mm

2

16 mm

2

25 mm

2

380 VAC

3

4 mm

2

4 mm

2

4 mm

2

6 mm

2

6 mm

2

400 VAC

3

4 mm

2

4 mm

2

4 mm

2

6 mm

2

6 mm

2

480 VAC

3

4 mm

2

4 mm

2

4 mm

2

6 mm

2

6 mm

2

english

Input voltage Phase < 10 feet 10–25 feet 25–50 feet 50–100 feet 100–150 feet

208 VAC

1

8 AWG

8 AWG

8 AWG

6 AWG

4 AWG

220 VAC

1

8 AWG

8 AWG

8 AWG

6 AWG

4 AWG

200–240 VAC

1

8 AWG

8 AWG

8 AWG

6 AWG

4 AWG

380 VAC

3

12 AWG

12 AWG

12 AWG

10 AWG

10 AWG

400 VAC

3

12 AWG

12 AWG

12 AWG

10 AWG

10 AWG

480 VAC

3

12 AWG

12 AWG

12 AWG

10 AWG

10 AWG