Component replaCement

6-2

powermax

45

Service Manual

dANgeR

ELECTRIC SHOCK CAN KILL

disconnect electrical power before performing any maintenance. All work requiring

removal of the power supply cover must be performed by a qualified technician.

Remove and replace the cover and Mylar

®

barrier

The first step in most maintenance and repair procedures for the Powermax45 is removing the cover and the Mylar

barrier. To protect your power supply, it is important to replace both items properly when the maintenance is complete.

Removal

1. Turn OFF the power, disconnect the power cord, and disconnect the gas supply.

2. Use a #2 Phillips screwdriver to remove the 2 screws from the handle on the top of the power supply. Gently pull

on the end panel nearest the screw you are removing to keep pressure on the screw. When the screw is almost

out, tilt the screwdriver slightly to help pull the screw out of the recessed hole.

3. Tip the end panels back slightly so that you can get the edges of the handle out from underneath them. Set the

handle and screws aside. Continue to tilt the end panels outward to release the fan side of the cover from its track.

Then lift the cover off the power supply.

4. Remove the Mylar barrier from the power-board side of the power supply. The Mylar barrier is flexible and can be

bent slightly for removal.