operation

powermax

45

Service Manual

4-3

45

30

40

Amperage adjustment knob
Set this knob to the gas test position (fully counter-clockwise) before adjusting the gas pressure with

the pressure regulator knob on the top of the power supply. Once the gas pressure is set, turn the knob

clockwise to set the output amperage. The torch will not fire when the knob is in gas-test position.

Mode switch and leds
The mode switch can be set in one of three positions:

• Continuous pilot arc to cut expanded metal or grate (top).
• Non-continuous pilot arc to cut metal plate (middle).
• Gouging (bottom).

After you change the mode switch, verify that the gas pressure is still set correctly. Different modes of

cutting require different pressure settings.

Rear controls

200–240 V CSA / 230 V Ce

400 V Ce / 480 V CSA

I

O

I

O

oN (I)/off (o) power switch

Activates the power supply and its control circuits.

operate the Powermax45

Follow the steps below to begin cutting or gouging with the Powermax45.

Connect the electrical power and gas supply

Plug in the power cord and connect the gas supply line. For more information about the electrical requirements and the

gas supply requirements of the Powermax45, see the Power Supply Setup section.