Install the consumables, Install the consumables -5, Powermax – Hypertherm Powermax45 Service Manual User Manual

Page 35

Advertising
background image

torch setup

powermax

45

Service Manual

3-5

Install the consumables

WARNINg

INSTANT-oN ToRCHeS

PlASMA ARC CAN CAUSe INJURy ANd bURNS

I

O

The plasma arc comes on im me di ate ly when the torch trigger is activated. Make sure

the power is off before changing consumables.

To operate the T45v torch, it must have a complete set of consumable parts installed: a shield or deflector, retaining

cap, nozzle, swirl ring and electrode.

With the power switch in the OFF (O) position, verify that the torch consumables are installed as shown.

Retaining cap

Nozzle

Electrode

Swirl ring

Note: Tighten only to finger-tight. Overtightening

will cause the torch to misfire.

Shield or deflector

There should be a small gap

between the consumables and the

torch handle. Air will blow out from

this gap during normal operation.

Advertising