Connect the gas supply

Connect the gas supply to the power supply using an inert gas hose with a 9.5 mm (3/8 inch) internal diameter and a

1/4 NPT quick-disconnect coupler or a 1/4 NPT x G-1/4 BSPP (CE units) quick-disconnect coupler.

CAUTIoN

Synthetic lubricants containing esters that are used in some air compressors will damage

polycarbonates used in the air regulator bowl.

Additional gas filtration

When site conditions introduce moisture, oil, or other contaminants into the gas line, use a three-stage coalescing

filtration system, such as the Eliminizer filter kit (128647) available from Hypertherm distributors. A three-stage filtering

system works as shown below to clean contaminants from the gas supply.

The filtering system should be installed between the quick-disconnect coupler and the power supply.

5.5 – 6.9 bar (80 – 100 psi) gas supply

(maximum 9.3 bar or 135 psi) with a flow

rate of at least 165.2 l/min (350 scfh). The

recommended flow rate and pressure is 170 l/min

at 6.2 bar (360 scfh at 90 psi).

Gas supply

Powermax45

Water and particle filter

Oil filter

Oil vapor filter