Powermax, Torch setup 3-20, Service manual – Hypertherm Powermax45 Service Manual User Manual

Page 50

Advertising
background image

torch setup

3-20

powermax

45

Service Manual

T45m unshielded consumables

Air flowrate (scfh)

Aluminum

Hot

320

english

Cold

360

Recommended

Maximum

Arc

current

(amps)

Material

thickness

Torch-

to-work

distance

(in)

Initial pierce

height

Pierce time

delay

(sec)

Cut

Speed

(ipm)

Voltage

(V)

Cut

Speed

(ipm)

Voltage

(V)

30

0.018 in

(26 Ga)

0.08

0.20 in

250%

0.0

350

122

400*

121

0.060 in

(16 Ga)

0.1

320

120

400*

118

0.075 in

(14 Ga)

0.2

225

121

280

119

45

0.060 in

(16 Ga)

0.08

0.20 in

250%

0.0

350

120

400*

116

0.075 in

(14 Ga)

320

120

400*

116

0.105 in

(12 Ga)

285

122

360

118

0.135 in

(10 Ga)

0.1

215

123

270

118

0.188 in

(3/16 in)

0.3

100

123

125

118

0.250 in

(1/4 in)

0.3

72

128

90

124

0.375 in

(3/8 in)

0.5

28

130

36

124

0.500 in

(1/2 in)

Edge start recommended

20

131

25

125

0.750 in

(3/4 in)

8

148

10

143

* Maximum cut speed is limited by the test table’s maximum speed (400 ipm).

Advertising