torch setup

3-14

powermax

45

Service Manual

T45m shielded consumables

Air flowrate (scfh)

Aluminum

Hot

320

english

Cold

360

Recommended

Maximum

Arc

current

(amps)

Material

thickness

Torch-

to-work

distance

(in)

Initial pierce

height

Pierce time

delay

(sec)

Cut

Speed

(ipm)

Voltage

(V)

Cut

Speed

(ipm)

Voltage

(V)

30

0.018 in

(26 Ga)

0.06

0.15 in

250%

0.0

360

117

400*

120

0.060 in

(16 Ga)

0.2

340

118

400*

121

0.075 in

(14 Ga)

215

118

270

121

45

0.060 in

(16 Ga)

0.06

0.15 in

250%

0.0

360

116

400*

114

0.075 in

(14 Ga)

340

117

400*

116

0.105 in

(12 Ga)

280

120

360

119

0.135 in

(10 Ga)

0.1

220

122

280

120

0.188 in

(3/16 in)

0.2

100

123

130

120

0.250 in

(1/4 in)

0.3

80

123

100

120

0.375 in

(3/8 in)

0.5

33

130

42

125

0.500 in

(1/2 in)

Edge start recommended

20

134

25

130

0.750 in

(3/4 in)

8

143

10

138