Component replaCement

6-14

powermax

45

Service Manual

7. Unscrew the filter bowl from the body and remove it.

8. Remove the glass filter tube by twisting it and pulling gently until it releases.

9. Unscrew the element from the filter body while being careful not to allow the element to rotate.

10. Screw the new element to the filter body.

11. Place the glass filter tube inside the filter bowl and screw the drain onto the bottom of the filter bowl. Reattach the

hose if you removed it earlier.

12. Reattach the filter bowl to the filter body, making sure that the drain and drain hose point toward the front edge of

the fan.

13. Reposition the filter assembly in the bracket and replace its retainer nut.

14. Reconnect the gas supply hose and press the drain hose onto the drain in the bottom of the power supply.

15. Reconnect the gas supply and check for leaks.

16. Slide the cover back onto the power supply. Position the handle over the holes in the top of the cover, then use the

2 screws to secure the cover.

17. Reconnect the electrical power and the gas supply.

Nut

Bracket

Filter bowl

Drain hose

Gas supply hose

Drain