Position the power supply

Locate the Powermax45 near an appropriate 200–240 volt power receptacle for CSA or CE 1-phase power supplies,

a 400 volt receptacle for 3-phase CE power supplies, or a 480 volt receptacle for 3-phase CSA power supplies. The

Powermax45 has a 3 m (10-foot) power cord. Allow at least 0.25 m (10 inches) of space around the power supply for

proper ventilation.

Prepare the electrical power

The maximum output voltage will vary based on your input voltage and the circuit’s amperage. Because the current

draw varies during startup, slow-blow fuses are recommended as shown in the following chart. Slow-blow fuses can

withstand currents up to 10 times the rated value for short periods of time.

Voltage configurations

The following chart shows the maximum rated output for typical combinations of input voltage and amperage.

Acceptable input voltages can be ±10% of the values given below.

CAUTIoN

Protect the circuit with appropriately sized time-delay (slow-blow) fuses and a line-disconnect

switch.

Model Input voltage Phase Rated output

Input

current at

6 kw output

Input

current

during arc

stretch

Recommended

slow-blow fuse

size

CSA

200–240 VAC

1

45 A, 132 V

34–28 A

55–45 A

50 A

208 VAC

1

45 A, 132 V

33 A

54.5 A

50 A

480 VAC

3

45 A, 132 V

8.5 A

12 A

15 or 20* A

CE

200–240 VAC

1

45 A, 132 V

34–28 A

55–45 A

35 or 50* A

400 VAC

3

45 A, 132 V

10 A

15.5 A

15 or 20* A

CE/CCC

220 VAC

1

45 A, 132 V

31 A

53 A

35 or 50* A

380 VAC

3

45 A, 132 V

11 A

14 A

15 A

* Use the higher amperage fuse for applications that require a long arc stretch.