Powermax – Hypertherm Powermax45 Service Manual User Manual

Page 127

Advertising
background image

component replacement

powermax

45

Service Manual

6-23

Item

description

1

Ribbon cable (J8 connector)

2

Heat sink assembly screw

3

J10 and J12 connectors

4

J13 connector

5

J14 connector

6

J15 connector

7

J16 connector

8

J18 connector

9

J22 connector

10

Work lead connector (J21)

11

Retaining screw

12

Ferrite (CE units only)

13

J20 connector

Item

description

14

Resistor screws (4)

15

Pressure relief vents

16

Capacitor screws (4)

17

J19 connector

18

J17 connector

19

Input bridge diode screw

20

Newer boards have a slot here

21

ON/OFF switch wires

22

J1 connector

23

J2 connector

24

J3 connector

25

IGBT attachment screws (2)

26

J4, J5, and J6 connectors

TP17

W

+ -

+ -

TP18

B

TP16

R

~280 VDC

~280 VDC

Newer 400 V Ce and 480 V CSA power board

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

2

2

2

11

11

Advertising
This manual is related to the following products: