Tab sensor setup (v-tab adjustments), Automatic tab sensor setup (v-tab) – Rena T-950 User Manual

Page 47

Advertising
background image

SETUP & OPERATION

41

Tab Sensor Setup (V-Tab adjustments)

The tab sensor adjustment must be performed each time you change the type of tab/stamp/label.
Adjusting the tab sensor values in the TABBER can be done automatically or manually.
The preferred method is automatic.

Automatic Tab Sensor Setup (V-Tab)

The following procedure assumes you have threaded tabs/stamps/labels, engaged the press rollers,
adjusted for proper media transport, and have set the tab pitch.

1. From the Start-Up screen select Advanced.






2. The screen at the right will appear.

Verify/Select the Media Sensor (Sensor 1
or Sensor 2) you are using,
then press the More… key.



3. The screen at the right will appear. Select

V-Tab.


4.

From the “Tab Sensor Setup” screen select
Automatic.





IMPORTANT: Make sure that the transport power switch is turned ON.
If the TABBER displays “Increase Transport Speed” or “Decrease Transport Speed”, adjust the
transport speed until the display shows “Feed 1 Product now”.


Press RUN to tab using Job 1.
Status: Pieces: 0
Mode Tab Jog Pass-Thru Advanced



Status: Advanced
V-Tab Backlight More… EXIT

Tab Sensor setup. Press EXIT when done.
V=1.67, Trip=0.98, Backing=0.30, Tab=1.67
Status: Advanced
Backing V Tab V Automatic EXIT

Sensor 1 is currently: Enabled
Choose: Sensor 1, or Sensor 2 to enable
Status: Advanced
Sensor 1 Sensor 2 More… EXIT

Advertising
This manual is related to the following products: