Cleaning the sensors, Media sensor test, Web (bin) sensor test – Rena T-950 User Manual

Page 64: Warning

Advertising
background image


MAINTENANCE

58

Cleaning the Sensors

There are four sensors in the tabber; the two media sensors located on the table of the tabber,
the tab sensor on the applicator head, and tab web (bin) sensor on the head assembly. These
sensors should be clean and free of accumulated paper dust. Use a vacuum with a soft brush
attachment or dry compressed air to remove the dust.

WARNING

DO NOT USE CHEMICALS or ABRASIVES OF ANY KIND ON THE SENSORS

The sensor locations are as follows:

MEDIA SENSOR TAB SENSOR

WEB (BIN) SENSOR

(Located under this plate.)

Media Sensor Test

There are two LED’s located on the exit side of the Media Sensor.

Green LED ON = Power Present
Orange LED ON = No Paper (not interrupted)
Orange LED OFF = Paper Present (interrupted)

If the orange LED is not on when there is no paper present, then the reflector may need to be cleaned.
If the orange LED comes “on” even when paper is present, then the sensor intensity may need to be
lowered. This is rare, but possible when high gloss media is being used. A qualified Rena service person
should make this adjustment.

Web (Bin) Sensor Test

There are two LED’s located on the exit side of the Tab Web Sensor.
Caution! To avoid tabs being driven from the tab reel and or personal injury from moving
rollers, please be sure to press the Emergency STOP button, before testing the Tab Web Sensor.

Green LED ON = Tabs/Stamp Present (interrupted)
Orange LED ON =

No Tabs/Stamps Present

Advertising