SETUP & OPERATION

43

Manual Tab Sensor Setup (V-Tab)

Under the following conditions, it may not be practical to use the automatic tab sensor setup feature.

 When using stamps or pre-addressed labels; since the automatic tab sensor setup process will

dispense/waste 2-3 stamps/labels, during the setup process.

 If the automatic tab sensor setup procedure didn’t give satisfactory results.

In these cases it is recommended that you adjust the tab sensor manually.

The following procedure assumes you have threaded tabs, selected the correct liner/backing type, adjusted
for proper media transport, and have properly set the tab pitch.

1. From the Start-Up screen select Advanced.






2. The screen at the right will appear.

Verify/Select the Media Sensor (Sensor 1
or Sensor 2) you are using,
then press the More… key.



3. The screen at the right will appear.

Select V-Tab.

4. The “Tab Sensor Setup” screen will now

appear.

There are two adjustments required to set the
tab sensor manually. One is the voltage
reference for the tab with its backing (Tab V).
The second is the voltage reference for the
space between tabs (Backing V).





Press RUN to tab using Job 1.
Status: Pieces: 0
Mode Tab Jog Pass-Thru Advanced

Tab Sensor setup. Press EXIT when done.
V=1.67, Trip=1.11, Backing=0.86, Tab=1.36
Status: Advanced
Backing V Tab V Automatic EXIT



Status: Advanced
V-Tab Backlight More… EXIT

Sensor 1 is currently: Enabled
Choose: Sensor 1, or Sensor 2 to enable
Status: Advanced
Sensor 1 Sensor 2 More… EXIT