SSi Manual Series 9010 – eSPP Programmer

Page 18


Loops


The current process variable is displayed at the top,
with each loop set point displayed beneath the
process variable. The operator can change the
process set point by touching the screen area below
the large process variable numbers. When pressing
the Temperature or % Carbon set point a numeric
keypad is displayed, showing the current value and
allowing you to enter a new set point by simply
pressing on the appropriate numeric keys. Once the
correct set point has been entered, press the OK key
to make the change. When the OK key is pressed the
display returns to the Loops Screen.

Also displayed are the probe millivolts, the probe temperature, and the CO Factor. The CO Factor can
also be adjusted from this screen. After pushing the COF button a numeric screen pad pops up and allows
the authorized personnel to make the appropriate change.

The Loops Screen also allows you to move back to the Status Screen or to the Recipe Screen by pressing
the Recipe button to view the program currently running on the Series 9010 controller.