Super Systems 9010 Series User Manual

Page 34

Advertising
background image

SSi Manual Series 9010 – eSPP Programmer

Page 34

CC_SP_L

The

Cascade Setpoint Limit

opcode will allow the user to set the upper and lower limits for the

cascade setpoint. The temperature data is the lower limit, and the atmosphere data is the upper
limit.

DELAY

This opcode is used when a short delay is needed. The option value is the delay time in seconds

.


DEV_AL

This deviation alarm opcode is used to turn the temperature or atmosphere deviation

alarms ON or OFF.

The option values are:

OFF, turns off both the temperature and atmosphere alarms;

TEMPERATURE, turns on the temperature alarm and turns off the atmosphere alarm;

ATMOSPHERE, turns on the atmosphere alarm and turns off the temperature alarm; and

BOTH, turns on both the temperature and the atmosphere alarms.

The band limit can be changed by the

SET_WAIT

opcode.


DOW_INQ

This opcode checks the real time clock for the day of the week. This is useful for performing

operations on a weekly basis on a specific day. The option data is the day of the week, i.e. SUN,
MON, TUE, WED, THU, FRI, and SAT.

EVT_IN

This opcode waits for an input event to be turned ON or OFF depending on the option value. The

option value is the event number followed by either ON or OFF.

If temperature data and or atmosphere data are specified, they are considered set points and will
be sent to the appropriate controller.


EVT_OUT

The

Event Output

opcode turns ON or OFF an output event based upon the option value. . The

option value is the event number followed by either ON or OFF.

If temperature data and or atmosphere data are specified, they are considered set points and will
be sent to the appropriate controller

.


G_Ramp

This is a guaranteed ramp opcode. The temperature and or atmosphere process value must be

within the wait limit band to allow the ramp timer to run. The option values are the ramp time in
hours and minutes, temperature and/or atmosphere set point. The band limit can be changed by
the

SET_WAIT

opcode.


G_SOAK

This is a guaranteed soak opcode. The temperature process value must be within the wait limit

band to allow the soak timer to run. The option value is the soak time in hours and minutes. The
band limit can be changed by the

SET_WAIT

opcode.

GHSOAK

This is a guaranteed soak high opcode. Anything below the high limit will satisfy the guarantee

and allow the soak timer to run. The option value is the soak time in hours and minutes. The
band limit can be changed by the

SET_WAIT

opcode.


GLSOAK

This is a guaranteed soak low opcode. Anything above the lower limit will satisfy the guarantee

and allow the soak timer to run. The option value is the soak time in hours and minutes. The
band limit can be changed by the

SET_WAIT

opcode.

GDELAY

This opcode is a guaranteed short delay, ensuring that the thermocouples are within the

deviation band. It guarantees on the temperature loop unless the load TCs are enabled, in which
case it guarantees against the load TC map for the specified number of seconds.

Advertising