Page 27

Systems Inc. and should not be adjusted without consulting SSI. The options are operator, supervisor, or
administrator.



Alarms


The 9010 controller

Alarms

screen allows the operator

to change the state of the programmer alarm. To make
a change, select the Programmer Alarm Normally
button, press Edit, and the status can be changed to
either Normally closed or Normally open.



Event Hold/Reset


The Event Hold/Reset menu option provides the user manual control of the operation based upon process
information. This will allow the setup of the digital inputs so that if a recipe needs to run only under a
specific condition, the condition can be based off of an
event input from a digital input through a switch. It can
be setup to run if the input is active or inactive. This can
also be based off of the relay contacts N.O./N.C. This is
useful when testing wiring and field devices.


Hold Instrument Number
Clicking on this value will display an input box from which
the user can select a new value. The range is 0 to 25.

Hold Minimum PV
Clicking on this value will display an input box from which
the user can select a minimum PV that would cause the
recipe to hold if below this new value. The range is -
32768 to 32767.

Hold Maximum PV
Clicking on this value will display an input box from which the user can select a maximum PV that would
cause the recipe to hold if above this new value. The range is -32768 to 32767.

Event for Program Run
Clicking on this value will display an input box from which the user can select an event input that would
cause the recipe to run based upon this new value. The recipe number to run can be selected under the
Program Number to Run option. This will allow a single program not a variable. The range is –1 (Disable)
to 15.

Event for Program Reset
Clicking on this value will display an input box from which the user can select an event input that would
cause the recipe to reset based upon this new value. The range is –1 (Disable) to 15.