Atmosphere instruments – Super Systems 9010 Series User Manual

Page 50

Advertising
background image

SSi Manual Series 9010 – eSPP Programmer

Page 50

Atmosphere Instruments

Controller

Source
Location

Write
Register

Read
Scale

Write Scale

Description

AC20

11

123

1

1

%C Actual

(Modbus Mode)

29

138

1

1

%C Setpoint

13

125

1

1

Probe Temperature

10

122

1

1

Probe Millivolts

20

130

10

10

%C Percent Output

34

142

1

1

CO Factor or Equivalent

35

143

1

1

H Factor or Equivalent

12

124

1

1

Dew Point

36

144

10

10

O2





Controller

Source
Location

Write
Register

Read
Scale

Write Scale

Description

Yokogawa 750

2

2

1

1

%C Actual

(Modbus Mode)

3

100

1

1

%C Setpoint

20

19

1

1

Probe Temperature

10

122

1

1

Probe Millivolts

4

4

10

10

%C Percent Output

0

0

1

1

CO Factor or Equivalent

0

0

1

1

H Factor or Equivalent

Controller

Source
Location

Write
Register

Read
Scale

Write Scale

Description

UDC 3300’s

1

0

1

1

%C Actual

(Modbus Mode)

3

2

1

1

%C Setpoint

6

5

10

10

Probe Temperature

5

4

10

10

Probe Millivolts

4

3

10

10

%C Percent Output

43

39

10

10

CO Factor or Equivalent

43

39

10

10

H Factor or Equivalent

Controller

Source
Location

Write
Register

Read
Scale

Write Scale

Description

Dualpro Loop 1

21

20

1

1

%C Actual

(Modbus Mode)

7

6

1

1

%C Setpoint

18

17

8

8

Probe Temperature

19

18

8

8

Probe Millivolts

41

40

41

41

%C Percent Output

4

3

1

1

CO Factor or Equivalent

5

4

1

1

H Factor or Equivalent