Super Systems 9010 Series User Manual

Page 37

Advertising
background image

SSi Manual Series 9010 – eSPP Programmer

Page 37

MV_INQ

The millivolt inquiry is used to wait for the probe millivolts to reach the value specified in the

atmosphere data.

The options are:

wait: the PV must be within the wait limit band specified to continue the recipe

wait up: the PV must be at or above the set point to continue the recipe

wait down: the PV must be at or below the set point to continue the recipe.

An explanation of wait, wait up, and wait down options can be found at the end of this chapter.

The

LIMIT

opcode immediately following this opcode sets a time limit on the wait.

A

BRANCH

opcode immediately following this opcode can be used to change the program flow

based on the inquiry results.

PIDLOAD

This opcode will load an alternate PID set from the controller memory. The temperature data

is the Loop 2 PID, the atmosphere data is the Loop 1 PID, and the option data is the Loop 3 PID. A
value of –1 will disable each Loop PID. 1 – 16 will load the corresponding alternate PID group.

PLC_SET_VAL

This opcode will set specially configured values in a slave PLC. Registers to be written to

must be described via the Configurator’s Recipe Management Group Opcode Control interface.
The temperature data is the value to write. The atmosphere data is the Write location. This can
be:

Quench SP

Endo SP

Ammonia SP

N2 SP

Methanol SP

Quench Sec

Drain Sec

T.C. Endo SP

T.C. N2 SP

FNC NH3 SP

T.C. Time

PLC Quench SP

Quench Type

The options are:

wait: the PV must be within the wait limit specified to continue the recipe

wait up: the PV must be above the lower wait limit to continue the recipe

wait down: the PV must be at or below the upper wait limit to continue the recipe.

Or nothing

.

PO_INQ

The percent output inquiry is used to test the actual percent output of the temperature and/or

atmosphere controller.
The options are:

wait: the PV must be within the wait limit band specified to continue the recipe

wait up: the PV must be at or above the set point to continue the recipe

wait down: the PV must be at or below the set point to continue the recipe.


An explanation of wait, wait up, and wait down options can be found at the end of this chapter.