Configuring snmp notifications for ipsec – H3C Technologies H3C S12500-X Series Switches User Manual

Page 207

Advertising
background image

195

[SwitchA-pkey-public-key-key1]D716D7DB9FCABB4ADBF6FB4FDB0CA25C761B308EF53009F7

1

01F7C62621216D5A572C379A32AC290

[SwitchA-pkey-public-key-key1]E55B394A217DA38B65B77F0185C8DB8095522D1EF044B465

E

8716261214A5A3B493E866991113B2D

[SwitchA-pkey-public-key-key1]485348

[SwitchA-pkey-public-key-key1] peer-public-key end

[SwitchA] quit

# Establish an SSH connection to the server 192.168.1.40 and specify the host public key of

the server.

<SwitchA> ssh2 192.168.1.40 publickey key1

Username: client001

[email protected]'s password:

After you enter the correct password, you successfully log in to Switch B.

284B

Publickey authentication enabled Stelnet client configuration
example

502B

Network requirements

As shown in

901H

Figure 58

, you can log in to Switch B through the Stelnet client that runs on Switch A and are

assigned the user role network-admin for configuration management. Switch B acts as the Stelnet server

and uses publickey authentication and the DSA public key algorithm.

Figure 58 Network diagram

503B

Configuration procedure

In the server configuration, the client public key is required. Use the client software to generate a DSA key
pair on the client before configuring the Stelnet server.

1.

Configure the Stelnet client:
# Assign an IP address to VLAN-interface 2.

<SwitchA> system-view

[SwitchA] interface vlan-interface 2

[SwitchA-Vlan-interface2] ip address 192.168.1.56 255.255.255.0

[SwitchA-Vlan-interface2] quit

# Generate a DSA key pair.

[SwitchA] public-key local create dsa

The range of public key size is (512 ~ 2048).

If the key modulus is greater than 512, it will take a few minutes.

Press CTRL+C to abort.

Input the modulus length [default = 1024]:

Generating Keys...

Advertising