LPU model

Description

Connector Port

quantity Port speed

Available

transceiver modules

LSXM1QGS12FX
1

12-port 40-Gigabit
QSFP+ fiber

Ethernet interface
card

MPO

LC

12 40

Gbps

QSFP+ module

QSFP+ DAC cable

QSFP+ to SFP+
DAC cable

LSXM1CGX8FX1

8-port 100-Gigabit

CXP fiber Ethernet
interface card

MPO

8

100 Gbps

CXP module

LSXM1CGP8FX1

8-port 100-Gigabit
CFP2 fiber Ethernet

interface card

LC

8

100 Gbps

CFP2 module

LSXM1TGT48FX1

48-port 10-Gigabit
copper Ethernet

interface card

RJ-45 48 10/1

Gbps

N/A

LSXM1GT48FX1

48-port
10/100/1000Ba
se-T copper

Ethernet interface

card

RJ-45 48

10/100/10
00 Mbps

N/A

Switching fabric modules

You can install one to six switching fabric modules for the switch. The switching fabric modules on the

switch must be the same type.

Table 30 Switching fabric module ordering guide

Chassis model

Available switching fabric module model

S12510-X AC

S12510-X DC

LSX1FAB10A1

LSX1FAB10B1

S12516-X AC

S12516-X DC

LSX1FAB16B1

LSX1FAB16S1

Power modules

CAUTION:

The power modules on a switch must be the same model.

The S12500-X switches use N + N (dual-line power supply) or N + 1 (one-line power supply) power

redundancy. You can install appropriate number of power modules according to the power supply mode

and system consumption. Make sure the total maximum output power of the ordered power modules is

greater than the system power consumption. H3C recommends that you reserve 20% of the maximum
output power.