Power consumption, Power module – H3C Technologies H3C SR6600 User Manual

Page 112

Advertising
background image

102

Power consumption

Table 23 Card power consumption

Model Actual

power consumption

Theoretical power consumption

RPE-X1

17 W

37 W

RSE-X1

32 W

75 W

MCP-X1

53 W

75 W

MCP-X2

53 W

75 W

FIP-10

33 W

50 W

FIP-110

60 W

75 W

FIP-20

55 W

75 W

FIP-210

105 W

125 W

FIP-240

156 W

200 W

SAP-48GBE

162 W

200 W

SAP-24GBP

125 W

150 W

SAP-48GBP

133 W

200 W

NOTE:

The theoretical power consumption, greater than the actual power consumption, is the upper power
consumption threshold defined to avoid power module overloading. You must use the theoretical power

consumption, rather than the actual power consumption, to calculate the total power consumption for
managing power modules and determining power module numbers.

Table 24 Fan power consumption

Model Power

consumption

SR6604 fan tray

30 W

SR6608 fan tray

30 W

Power module

The router supports hot-swappable AC and DC power modules, but an AC power module and a DC

power module cannot work together. You can install one or, for redundancy, multiple power modules,
but the power modules in use must have the same specifications.

Advertising