Installing an rse-x1 mpu, Installing an mcp mpu – H3C Technologies H3C SR6600 User Manual

Page 26

Advertising
background image

16

6.

Fasten the captive screws with a Phillips screwdriver.

7.

If the router is powered off, power it on.
The RUN LED (green) flashes fast (at 8 Hz). It flashes slowly (at 1 Hz) after the RPE-X1 application
is loaded. This means that the RPE-X1 runs correctly. For the LED description, see "

Appendix C

LEDs

."

Installing an RSE-X1 MPU

The RSE-X1 MPU is hot swappable and you must perform the remove slot number command to stop the
module before you remove it.
When two RSE-X1 MPUs are installed on the router, the ACT LED (green) is steady on.
To install an RSE-X1:

1.

Locate the slot to install the RSE-X1 (slot 1 or slot 2, the figures illustrate how to install an RPE-X1 to
slot 1).

2.

Remove the captive screws on the filler panel with a Phillips screwdriver.

3.

Use even pressure to gently push the RSE-X1 into slot 1 along the slide rails, and then push the
ejector levers inward to lock the RSE-X1 in position.

Figure 13 Inserting the RSE-X1 into the slot

4.

Fasten the captive screws with a Phillips screwdriver.

5.

If the router is powered off, power it on.
After the RSE-X1 is powered on, the RUN LED (green) flashes fast (at 8 Hz). It flashes slowly (at 1
Hz) after the RSE-X1 application is loaded. This means that the RSE-X1 runs correctly. For the
RSE-X1 LED description, see "

Appendix C LEDs

."

Installing an MCP MPU

The MCP supports FIP 10 and FIP 20 only.