H3C Technologies H3C SR6600 User Manual

Page 149

Advertising
background image

139

LED Status

Description

(green)

Run LED

Off

No power input is available, or the MCP-X1 has
failed.

Slow flashing
(1 Hz)

The MCP-X1 is operating correctly.

Fast flashing (8
Hz)

The application software is being loaded (in this
case, never power off the device or hot-swap the
MCP-X1; otherwise the MCP-X1 might be

damaged).

(green)

Active LED

Off

The MCP-X1 is in standby state.

Steady on

The MCP-X1 is in active state.

(red)

Power
management

alarm LED

Off

The system power module is normal.

Steady on

The system power is insufficient.

(red)

Alarm LED

Off

The system is operating correctly and there is no
alarm.

Steady on

A fault has occurred to the system or the available
power is insufficient. In this state, check the system

log immediately.

LINK LED

Off

The corresponding interface is not connected.

Steady green

A 1000 Mbps link is present.

Steady yellow

A 10/100 Mbps link is present.

ACT LED

Off

No data is being received or transmitted.

Flashing yellow Data is being received or transmitted.

SFP+LINK/ACT

Off

No link is present.

Steady green

A 10 Gbps link is present.

Flashing green

Data is being received or transmitted at a rate of 10
Gbps.

Steady yellow

Transceiver module check has failed.

(yellow/green)

SFP0 through
SFP3

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

Data is being received or transmitted at a rate of
1000 Mbps.

Steady yellow

A 100 Mbps link is present.

Flashing yellow

Data is being received or transmitted at a rate of
100 Mbps.

CAUTION:

Do not remove the CF card when the CF LED is flashing. Otherwise, the file system on the CF card will be
damaged.

Advertising