5. Enter the control network IP address and other network settings.
6. For SNMP Configuration, enter the IP address of the SNMP manager PC.
You can also enter IP addresses for other SNMP managers to which you want to send SNMP
trap messages.
Refer to related topics about Grass Valley recommended deployment and monitoring solutions
in "K2 Release Notes".
7. Click
OK
to save settings and close.
8. In Storage Utility click
View | Refresh
.
Next, bind disk modules.
Binding disk modules - Proxy Storage
Prerequisites for the K2 RAID chassis are as follows:
•
Fibre Channel cable(s) connected
•
Ethernet cable(s) connected
•
Power on
Prerequisites for the optional K2 RAID Expansion chassis (if present) are as follows:
•
Fibre channel cable(s) connected
•
Power on
NOTE: Binding destroys all user data on the disks.
1. If you have not already done so, launch Storage Utility from the K2Config application.
2. As prompted, wait while Storage Utility gathers system information, then Storage Utility opens.