Binding disk modules - proxy storage – Grass Valley GV STRATUS Installation v.3.1 User Manual

Page 351

Advertising
background image

5. Enter the control network IP address and other network settings.

6. For SNMP Configuration, enter the IP address of the SNMP manager PC.

You can also enter IP addresses for other SNMP managers to which you want to send SNMP
trap messages.

Refer to related topics about Grass Valley recommended deployment and monitoring solutions
in "K2 Release Notes".

7. Click

OK

to save settings and close.

8. In Storage Utility click

View | Refresh

.

Next, bind disk modules.

Binding disk modules - Proxy Storage

Prerequisites for the K2 RAID chassis are as follows:

Fibre Channel cable(s) connected

Ethernet cable(s) connected

Power on

Prerequisites for the optional K2 RAID Expansion chassis (if present) are as follows:

Fibre channel cable(s) connected

Power on

NOTE: Binding destroys all user data on the disks.

1. If you have not already done so, launch Storage Utility from the K2Config application.

2. As prompted, wait while Storage Utility gathers system information, then Storage Utility opens.

2013 12 19

GV STRATUS Installation and Service Manual

351

Complete system set up and configuration

Advertising
This manual is related to the following products: