Grass Valley K2 Storage System Instruction Manual v.3.2 Sep.24 2007 User Manual

Page 216

Advertising
background image

216

K2 Storage System Instruction Manual

September 7, 2007

Chapter 5 Installing the Level 3R Storage System

g. Close the Progress Report and repeat these steps for other unbound disks. If

specified by your system design, you can bind some disks as Hot Spares, as
explained in

“Binding Hot Spare drives” on page 751

. When you are done, if

you did not bind any extra Hot Spares, you should have the following results:

For Level three redundant storage, on the primary RAID chassis you should
have two RAID 1 RANKs of two disks each, one Hot Spare Disk, and two RAID
5 RANKs of five disks each. For each optional Expansion chassis, you would
have an additional three RAID 5 RANKs of five disks each. If using RAID 6,
RANKs are six disks each.

h. Click

Close

in Progress Report window.

4. Restart the K2 Media Server.

NOTE: Make sure start up processes on the K2 Media Server are complete before
proceeding.

5. Continue with the next procedure

“Creating a new file system”

.