Level 3R system power-on procedure

Level 3R power-on procedure page 2

Power on the primary
media file system/
database K2 Media
Server. This is the
server that was
primary when you last
powered down the K2
Storage System.

From the control
point PC, in the K2
System
Configuration
application, open

Server Control

Panel

.

Put the K2 Media Server into service:
In Server Control Panel, click

Start

to

start Failover Monitor.

No

In Server Control Panel,
check the Failover Monitor
indicator.

Yes

No

Yes

Power on the primary
FTP/bridge K2 Media
Server.

From the control point PC, at
the command prompt, ping
the K2 Media Server.

No

Yes

In Server
Control Panel,
check the
media file
system
indicator.

K2

Media Server

responds to ping?

Elapsed time:

3 minutes

Green

indicator?

Elapsed time:

3 minutes

Green

indicator?

Elapsed time:

30 seconds

Continue with page 3 of Level 3R power-on procedure