Powering on the hp procurve switch – Grass Valley K2 Storage System Instruction Manual v.3.2 Sep.24 2007 User Manual

Page 595

Advertising
background image

September 7, 2007

K2 Storage System Instruction Manual

595

Powering on Level 10, 20, 30, and Nearline 10 RAID storage devices

Powering on Level 10, 20, 30, and Nearline 10 RAID storage
devices

Use the following procedure to power on and verify proper operation of RAID storage
devices.

1. Verify power and cabling.

2. Press and hold down the power button on the controller, as shown.

If the RAID chassis has two controllers, you can press the power button on either
controller. You do not need to press both power buttons.

Pressing the power button on a controller also powers on any connected Expansion
chassis. There are no power buttons on Expansion chassis.

3. Release the power button when the Power Good LED on the power supply is

illuminated. This takes 1-3 seconds.

4. Wait while the primary RAID chassis performs self-test and initialization. This

takes about four minutes. While this is taking place, the RDY LED is illuminated
with a steady on light.

5. Watch for the RDY LED to begin blinking at one second intervals. The LED might

turn off and back on two times before starting the one second blink pattern. When
the RDY LED is blinking at one second intervals, the self-test and initialization is
complete and the chassis is ready for use.

Powering on the HP ProCurve switch

Use the following procedure to power on and verify proper operation of the HP
ProCurve switch.

1. Power up the switch.

2. Watch LEDs to verify proper operation. The diagnostic self test LED Behavior is

as follows:

• Initially, all the status, LED Mode and port LEDs are on for most of the duration

of the test.

• Most of the LEDs go off and then may come on again during phases of the self

test. For the duration of the self test, the Test LED stays on.

If the ports are connected to active network devices, the LEDs behave according to
the LED Mode selected. In the default view mode (Link), the LEDs should be on.

BBU IN

MODEM

FLT/LNK

HPE

FLT

A/L

BACKUP

ACT/LNK

LNK/ACT

FLT

HP

5 4 3 2

RDY

LAN

BAT

MNT

ACS

MC

DP1

DP0

HP

1 0

BBU IN

MODEM

FLT/LNK

HPE

FLT

A/L

BACKUP

ACT/LNK

LNK/ACT

FLT

HP

5 4 3 2

RDY

LAN

BAT

MNT

ACS

MC

DP1

DP0

HP

1 0

Power Cords

(115V/2

3

0V)

RDY
LED

RDY
LED

Power Good

LED

Power Good

LED

Advertising