Chapter 10 installing the level 20r storage system – Grass Valley K2 Storage System Instruction Manual v.3.2 Sep.24 2007 User Manual

Page 478

Advertising
background image

478

K2 Storage System Instruction Manual

September 7, 2007

Chapter 10 Installing the Level 20R Storage System

iSCSI Bridge Server
Configuration

This page manages the
components that bridge
between iSCSI (the GigE
media network) and the
Fibre Channel connection to
the RAID storage. You
configure network settings
on the iSCSI adapters and
the page validates that the
Fibre Channel adapter is in
place and that the media
RANKs are visible as iSCSI
targets.

NOTE: The iSCSI
adapters on this
server must be on a
different subnet
than those on its
redundant server
partner.

Select

Backup

.

Select an iSCSI adapter and click

Modify

. A network configuration

dialog box opens. Enter the media network IP address and subnet mask
and click

Apply

.

Do the same for the other iSCSI adapter.
To verify drives, click

Check

then

View Target Drives

. You should see

all your media drives listed.
Click

Next

.

Database Server
Configuration

You do not need to enter or configure anything on this page.
Click

Next

.

On this page…

Do this…