Grass Valley Kaleido-Solo Installation v.5.00 User Manual
Page 40
GUIDE TO INSTALLATION AND OPERATION
36 | Kaleido-Solo
Audio in dBU level at 0 dBFS
This configuration is used to set up
analog level meters (listed below). Furthermore, it‟s the reference level used to
convert dBFS to dBU.
Analog level meters affected by this parameter:
VU METER (+4dBu) (IEC60268-17 (0VU = +4dBu)) Analog VU
VU METER (0dBu) (IEC60268-17 (0VU = 0dBu)) Analog VU
UK PPM (IEC60268-10 type IIa) Analog peak
EBU PPM (IEC60268-10 type IIb) Analog peak
NORDIC PPM (IEC60268-10 type I) Analog peak
DIN PPM (IEC60268-10 type I) Analog peak
Stereo Assignment
Select input channels (by pair) for each of the eight available ALMs or the downmix output (KS-910 only) or from the
logical Dolby E source (KS-910 only). To change the appearance of ALMs, see section 5.5.3.
Left Side 5.1 Assignment
Select the channels you want to assign to left side 5.1 ALMs.
Right Side 5.1 Assignment
Select the channels you want to assign to right side 5.1 ALMs.