Grass Valley Kaleido-Solo Installation v.5.00 User Manual
Page 82
GUIDE TO INSTALLATION AND OPERATION
78 | Kaleido-Solo
on the border of the screen.
Reset Loudness:
Reset loudness measurement (see section 5.4.7).
Run/Pause Loudness:
Toggle the loudness measurement between run and pause based on the GPI input
level (Inactive = Run, Active = Pause) (see section 5.4.7).
GPI Output Trigger
You can define a trigger to activate the GPI output. Here are the possibilities:
None:
Nothing.
GPI Input 1
Loop GPI Input 1 status to GPI Output.
GPI Input 2
Loop GPI Input 2 status to GPI Output.
Loudness Meter 1 Error
Activate the GPI output when loudness measurement 1 is in error (alarm)
(see section 5.5.2).
Loudness Meter 2 Error
Activate the GPI output when loudness measurement 2 is in error (alarm)
(see section 5.5.2).