8.1 Axis Setting Commands

8-11

8

Command Reference

8.1.3 Acceleration Time Change (ACC)

(1) Overview

The Acceleration Time Change command (ACC) changes the acceleration time or acceleration rate of the axis
for which one of the following axis move commands is executed.

• Positioning (MOV)
• Set Time Positioning (MVT)
• External Positioning (EXM)

The acceleration time for up to 16 axes can be changed at once. The acceleration time of any axis unspecified in
the command block is not changed.
The acceleration time changed by the ACC command remains until it is reset by the next ACC command.

Fig. 8.5 Acceleration Time Change (ACC)

• The Acceleration Time Change command (ACC) changes the acceleration time for positioning related commands

MOV, EXM, and MVT. Use an IAC command to set the acceleration time for interpolation related commands, MVS,
MCW, MCC, and SKP.

• All motion modules, except the PO-01 module, support ACC, DCC, and SCC commands.

Use of these commands with the PO-01 module requires the following combination of MP2000-series Machine Con-
troller and PO-01 module versions.

Motion Programs

Sequence Programs

Applicable

Not applicable

MP2000 Series Version Number

PO-01 Module Version Number

Ver.2.46 or later

Ver.1.06 or later

Speed (V)

Time (t)

Before acceleration time change

Speed (V)

Time (t)

After acceleration time change

INFO