4 Motion Programs

4.4.2 Controlling the Motion Program Directly from an External Device

4-12

4.4.2 Controlling the Motion Program Directly from an External Device

The M-EXECUTOR Module has a function used to allocate the M-EXECUTOR’s control register to a desired
register.
With this function, data can automatically be exchanged between the M-EXECUTOR’s control register and the I/
O register connected to an external device. Thus, this function allows an external device to directly control the
motion program.
The following diagram shows a setting example for this function.

The allocated interlock contact is used as an interlock for motion program execution. Always allocate an inter-
lock contact in Allocation Contact interlock when allocating a register in Allocation register.
The following processes are executed according to the ON/OFF status of the allocated interlock contact.

• When the allocated interlock contact is ON, the allocated register exchanges data with the M-EXECUTOR control reg-

ister in a high-speed scan cycle, and motion program execution is enabled during the data exchange.

• When the allocated interlock contact is OFF, the allocated register does not exchange data with the M-EXECUTOR

control register, and motion program execution is disabled.

• When the Allocation Contact interlock is changed from ON to OFF while the motion program is running, the motion

program will stop running and the axes will stop moving. At this moment, the motion program alarm “1Bh: Emergency
Stop Command in Execution” will occur, and bit 8 (Program alarm occurring) of the status flag will turn ON.

Use the following procedure to restart the motion program.

1. Set the interlock contact from OFF to ON.
2. Set bit 5 (Program reset and alarm reset request) of the control signal to ON.
3. Confirm that bit 8 (Program alarm) of the status flag turns OFF.
4. Set bit 5 (Program reset and alarm reset request) of the control signal to OFF.
5. Set bit 0 (Program operation start request) of the control signal to ON.

Signals from external device

Program number

Program operation start

Program pause

Program stop, etc.

Allocated

interlock

contacts

References the

M-EXECUTOR

control registers

Set desired registers for Allocation register and

Allocation Contact interlock.

Allocated registers

Program number

Data will be

exchanged

in high-speed

scan cycle.

Host PLC
Touch panel
Switch
LED, etc

External devices

MPM001

END

Execution control by

motion management function

Motion program

VEL [a1] 5000 [b1]..

FMX T10000000;

IAC T25;

IDC T30;

MOV [a1] 300. [b1]..

MVS [a1] 200. [b1]..

.

.

.

.

Status

Control signal

M-EXECUTOR Register Allocation window

Override for interpolation

INFO