8.1.5 S-curve Time Constant Change (SCC)

8-24

(3) Setting Items for SCC Command

Motion Image

Specify a numerical value or register for the S-curve time constant of each axis using an SCC command.
The reference range of the S-curve time constant depends on the motion module to be used:

• For SVA-01, PO-01, and SVR modules, the reference range is specified by motion setting parameter

OW

3A (Filter time constant).

• For built-in SVB and SVB-01 modules, the reference range is specified by the SERVOPACK parameter

Average Movement Time.

The following table shows the reference range of S-curve time constants for each motion module model.

• If a reference value of more than 6553 ms is input, a motion program alarm will occur regardless of the motion module

model.

• If a reference value exceeds the upper limit (511 to 6553 ms) when using a built-in SVB or SVB-01 module, bit 1 of

motion monitoring parameter IL

02 is set to 1 (Set parameter error), and the upper limit (510 ms) is set for the Aver-

age Movement Time of the SERVOPACK parameter.

Speed (V)

Time (t)

S-curve time constant (SCC)

When the acceleration/deceleration filter is disabled

Motion Module

SCC Command

Reference Range (ms)

Remarks

SVA-01

0 to 6553

SVB-01,

Built-in SVB

0 to 510

With the SGD-N, SGDB-N, SGDH+NS110/NS115, SGDS, SGDX, or
SGDV SERVOPACK

With the SGDJ SERVOPACK, the S-curve acceleration/deceleration can-
not be used since the SERVOPACK does not have a parameter for Aver-
age Movement Time.

PO-01

0 to 6553

SVR

0 to 6553

INFO