Ocx 8800, Instruction manual, Electronics housing assembly – Emerson ROSEMOUNT OCX 8800 User Manual

Page 92

Advertising
background image

Instruction Manual

IM-106-880, Rev 1.0

January 2007

OCX 8800

6-30

Remove Solenoid Valves

1. Disconnect solenoid leads from mating terminal connector.
2. Remove top nut of solenoid valve (15 or 16, Figure 6-22).
3. Remove the solenoid coil assembly and washer.
4. Unthread and remove solenoid valve base.

Remove EMI Filter and Terminal Block

1. Disconnect EMI filter wiring (Figure 6-23) at terminal block (3).
2. Disconnect EMI filter wiring at AC power input terminal block on

electronic stack.

3. Unbolt and remove EMI filter (1) from electronic stack.
4. Remove ground wire (2) from terminal block (3).
5. Unbolt and remove terminal block (3) from electronic stack.

Figure 6-23. Removal/

Installation of EMI Filter

Electronics Housing
Assembly

Install EMI Filter and Terminal Block

1. Install replacement EMI filter (1, Figure 6-23) and/or terminal block (3)

on electronic stack.

2. Refer to wiring details in Figure 6-23. Connect EMI filter wiring and

ground wire (2) at terminal block (3).

3. Connect EMI filter wiring at AC power input terminal block on electronic

stack.

1

2

3

37390083

Brown

Blue

Green

Green

Green

Brown

Blue

Advertising