Table 3-1 – Sun Microsystems SUN STOREDGETM 5310 NAS User Manual

Page 214

Advertising
background image

3-14

Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004

TABLE 3-1

Lights on the Back of a Command Module

Location

Component
Light

Color

Normal Status

Problem
Status

Procedure

Controller

1

Host
Connector
1 Link
Indicator

Green

On

Off

“Replacing
a Drive”
on page 7-
36

2

Host
Connector
1 Speed
Indicator

Green

On - 2 Gb/s data rate
Off - 1 Gb/s data rate

Not
Applicable

3

Host
Connector
2 Link
Indicator

Green

On

Off

4

Host
Connector
2 Speed
Indicator

Green

On - 2 Gb/s data rate
Off - 1 Gb/s data rate

Not
Applicable

5

Ethernet
link
indicator

Green

On - Connection active
Off - Connection inactive

Not
Applicable

Not
Applicable

6

Ethernet
100Base TX
indicator

Green

On - 100BaseTX
connection
Off - 10BaseT (or
inactive)

Not
Applicable

7

Battery
Charging/
Charged

Green

On -battery charged
Flashing - battery
charging

Off

“Replacing
a
Controller
Battery”
on page 7-
29