Troubleshooting Overview

1-23

Write-back cache
is disabled.

Controller Cache Disabled:
Either AC power or UPS is not charged
completely.
Action: 1 - If AC power has failed,
restore system power. 2 - If after a long
time UPS is not charged completely,
check UPS.
Severity = Warning

Cache
Disabled

write-back cache
for ctrl x disabled

Write-back cache
is enabled.

Controller Cache Enabled:
System AC power and UPS are reliable
again. Write-back cache is enabled.
Severity = Notice

Cache
Enabled

write-back cache
for ctlr n enabled

The UPS is
shutting down.

UPS shutdown:
The system is being shut down
because there is no AC power and the
UPS battery is depleted.
Severity = Critical

!UPS: Shutting
down

UPS Failure

UPS failure:
Communication with the UPS unit has
failed.
Action: 1. Check the serial cable
connecting the UPS unit to one of the
CPU enclosures, OR
2. Check the UPS unit and replace if
necessary.
Severity = Critical

EnvUpsFail

U25 UPS
failure

UPS:
Communication
failure.

TABLE A-3

UPS Error Messages

Event

E-Mail Subject: Text

SNMP Trap

LCD Panel

Log