2 post error beep codes, Post error beep codes 27, Table 2-11 – Sun Microsystems SUN STOREDGETM 5310 NAS User Manual

Page 73: Bmc-generated post b

Advertising
background image

Chapter 2

NAS Head

2-27

2.6.2

POST Error Beep Codes

The tables in this section list the POST error beep codes. Prior to system video
initialization, the BIOS and BMC use these beep codes to notify users of error
conditions.

8305

Hotswap controller failed to function

Yes

8420

Intelligent System Monitoring chassis opened

Yes

84F1

Intelligent System Monitoring forced shutdown

Yes

84F2

Server Management Interface failed

Yes

84F3

BMC in update mode

Yes

84F4

Sensor Data Record (SDR) empty

Yes

84FF

System event log full

No

8500

Bad or missing memory in slot 3A

Yes

8501

Bad or missing memory in slot 2A

Yes

8502

Bad or missing memory in slot 1A

Yes

8504

Bad or missing memory in slot 3B

Yes

8505

Bad or missing memory in slot 2B

Yes

8506

Bad or missing memory in slot 1B

Yes

8601

All memory marked as fail: forcing minimum back online

Yes

TABLE 2-11

BMC-Generated POST Beep Codes

Beep Code

1

Description

1

One short beep before boot (normal, not an error)

1-2

Search for option ROMs. One long beep and two short beeps on checksum
failure.

1-2-2-3

BIOS ROM checksum

1-3-1-1

Test DRAM refresh

1-3-1-3

Test 8742 keyboard controller

1-3-3-1

Auto size DRAM. System BIOS stops execution here if the BIOS does not
detect any usable memory DIMMs.

1-3-4-1

Base RAM failure. BIOS stops execution here if entire memory is bad.

TABLE 2-10

Extended POST Error Messages and Codes (Continued)

Error Code

Error Message

Pause On Boot